MCPInstall
awslabs avatar

biomarker-discovery

Reason about biomarker discovery and validation in HCLS — classifying biomarker intent, choosing feature-selection and cross-validation strategies, avoiding leakage, and planning external replication. Use when the user asks to discover, develop, or validate a biomarker; select features from high-dimensional omics or clinical data; design a validation study; choose evaluation metrics; justify sample size; combine multi-omics signals; or assess clinical utility. Triggers include "discover a biomarker", "validate biomarker", "prognostic vs predictive", "feature selection", "LASSO vs elastic net", "nested cross-validation", "data leakage", "C-index", "time-dependent AUC", "decision curve analysis", "external validation cohort", "events per variable", "optimism-corrected", "multi-omics integration", "clinical utility of a biomarker", "is this biomarker ready".

Installs
82
Last 24h
—
Trending rank
—
Security
Not audited

Install

Works with every agent the skills CLI supports.

npx skills add https://github.com/awslabs/hcls-agent-skills --skill biomarker-discovery
  1. 01

    Install

    Run the command in your project. The CLI asks which agents to install for.

  2. 02

    Describe the task

    Ask your agent for something this skill covers. It loads biomarker-discovery automatically when relevant.

  3. 03

    Review the result

    The agent follows the SKILL.md steps, scripts and references bundled with the skill.

SKILL.md

The instructions your agent reads when the skill is triggered.

Biomarker Discovery and Validation

Overview

This skill teaches the agent how to think about biomarker discovery and validation, not how to run a specific pipeline. A biomarker is only useful if three things line up: (1) the intent is clearly defined (prognostic, predictive, or diagnostic), (2) the discovery statistics are honest (no leakage, appropriate penalization, nested resampling), and (3) the validation plan reaches external replication and demonstrates a clinical decision change.

Use this skill to interrogate proposals, spot methodological weaknesses, and guide the user toward the right design before code is written.

Usage

Invoke this skill when the user:

  • Describes a candidate marker (gene, protein, imaging feature, EHR variable, composite score) and asks how to develop or validate it.
  • Has a high-dimensional dataset (transcriptomics, proteomics, radiomics, methylation) and wants to select features.
  • Asks which cross-validation scheme, metric, or sample size is appropriate.
  • Claims a biomarker "works" based on a single AUC on a single cohort.
  • Wants to combine multiple omics layers or modalities.
  • Asks whether a biomarker is ready for clinical use or regulatory submission.

The agent should respond by:

  1. Clarifying intent — force a prognostic/predictive/diagnostic classification before anything else.
  2. Auditing the data — sample size, event counts, site structure, missingness, time origin.
  3. Recommending a design — feature selection, resampling, metrics, validation tier.
  4. Naming the leakage risks specific to the user's setup.
  5. Stating what "validated" would mean for this biomarker in this context.

Response Format

  • Lead with the direct recommendation or classification (≤3 sentences)
  • Structure as: recommendation → justification (citing specific criteria/thresholds) → caveats
  • Use tables for comparisons; bullet points for criteria lists
  • Omit background the user already knows — they asked the question
  • Target: 200-400 words unless the user requests exhaustive detail The decision trees and frameworks in this skill are for internal reasoning only. Apply them to reach your conclusion, but do not reproduce them in your response. Present only the final recommendation with supporting evidence.

Core Concepts

1. Biomarker Intent Determines Everything

The first question is always: what decision is this biomarker supposed to inform?

IntentQuestion answeredMinimal designKey estimand
PrognosticWhat is this patient's outcome regardless of treatment?Single-arm / observational cohort with outcome follow-upHazard ratio, C-index, calibration
PredictiveWho benefits more from treatment A vs B?RCT or well-emulated target trial with both armsTreatment × biomarker interaction
DiagnosticDoes this patient have the disease now?Case–control with full disease spectrumSensitivity, specificity, PPV/NPV

Consequences of the classification:

  • A prognostic claim cannot be made from a predictive design without a single-arm reference, and a predictive claim cannot be made from a single-arm cohort — there is no counterfactual arm.
  • A diagnostic biomarker evaluated only in clear cases vs healthy controls will overstate performance; it must be tested across the clinical spectrum it will be used in (mild, early, comorbid, mimics).
  • Confusing prognostic with predictive is the single most common error in oncology biomarker papers. If the user claims "patients with high X did better on drug Y," ask whether the same is true on the control arm — if yes, it is prognostic, not predictive.

2. Feature Selection Strategy

Pick based on the shape of the problem, not familiarity.

MethodStrengthWhen it fails
LASSO (L1)Sparse solutions, interpretable, fastPicks one arbitrary feature from correlated groups
Elastic net (L1 + L2)Handles correlated features, groups themTwo hyperparameters to tune
Random (survival) forest importanceCaptures non-linearities and interactionsBiased toward high-cardinality features; importance ≠ causation
Stability selectionReports features selected in >60% of subsamples; controls false discoveriesComputationally heavier; needs a base selector (usually LASSO)
Univariate filteringSimpleIgnores multivariate structure; almost always wrong as a sole method in high-d

Decision tree: which feature selection method?

Start
│
├── Is n < p (more features than samples)?
│     ├── Yes → Use penalization (LASSO / elastic net) OR stability selection.
│     │         Never rely on univariate filtering alone.
│     └── No  → Continue.
│
├── Are features strongly correlated (e.g., gene modules, radiomic clusters)?
│     ├── Yes → Elastic net (groups correlated features) or
│     │         group LASSO if groupings are known a priori.
│     └── No  → LASSO is fine.
│
├── Do you suspect non-linear effects or interactions?
│     ├── Yes → Random forest / gradient-boosted trees for importance,
│     │         confirm with permutation importance (not impurity-based).
│     └── No  → Stay with linear penalized models.
│
└── Need reproducibility / publication-grade selection?
      └── Wrap whatever base method above in stability selection
          (subsample → refit → keep features chosen in ≥60% of runs).

3. Nested Cross-Validation is Non-Negotiable

Biomarker discovery must use nested CV:

  • Outer loop — estimates generalization performance on held-out folds.
  • Inner loop — performs feature selection and hyperparameter tuning on training folds only.

Rules:

  • Patient-level splits. Never split rows when a patient contributes multiple samples (longitudinal labs, multiple lesions, bilateral imaging). Leakage across folds via shared patients is the most common silent inflator of performance.
  • Stratify by outcome (and by site/batch when feasible).
  • Everything learned from data goes inside the inner loop: feature selection, imputation parameters, normalization statistics, scaler means/SDs, batch-correction fits, PCA loadings.
  • Report the distribution across outer folds, not just the mean — high variance across folds is a warning sign.

4. Data Leakage — The Usual Suspects

Leakage invalidates everything downstream. Check for:

  1. Feature selection on the full dataset before CV. The selected features already "know" the test labels. Always select inside the CV loop.
  2. Temporal leakage. A lab is ordered because clinicians already suspect the outcome. The feature's presence/absence itself encodes the label. Define a clean time origin (e.g., admission, diagnosis, randomization) and only use data available before it.
  3. Outcome-in-features. Variables that are definitionally downstream of the outcome (e.g., "received hospice" predicting death; "tumor stage IV" predicting metastasis) are circular.
  4. Preprocessing leakage. Computing normalization means, imputation medians, scaler statistics, or PCA on the full dataset leaks test distribution into training. Fit on training folds only, apply to test.
  5. Batch/site leakage. If all cases come from Site A and all controls from Site B, the model learns site, not biology.
  6. Target leakage via proxies. Encounter ID, physician ID, or order timestamps can proxy outcome.

5. Evaluation Metrics by Intent

Choosing the wrong metric hides or inflates effects.

  • Prognostic (time-to-event):
    • C-index (Harrell's or Uno's for censoring).
    • Time-dependent AUC at clinically relevant horizons (e.g., 1, 3, 5 years).
    • Calibration (calibration-in-the-large, calibration slope, calibration plots). Discrimination without calibration is insufficient.
  • Predictive:
    • Treatment × biomarker interaction term (p-value and effect size).
    • Subgroup-specific hazard ratios or risk differences — both point estimates and CIs.
    • Qualitative interaction (benefit flips direction) is stronger evidence than quantitative interaction (benefit magnitude differs).
  • Diagnostic:
    • Sensitivity and specificity at the pre-specified clinical threshold, not the one that maximizes Youden's J on the test set.
    • AUROC as a summary; AUPRC when prevalence is low and positive class is the focus.
    • PPV and NPV — these are prevalence-dependent. Report the prevalence assumed and re-estimate PPV/NPV at the deployment prevalence.

Always report confidence intervals (bootstrap or analytic) alongside point estimates.

6. Validation Hierarchy

A biomarker graduates through tiers. Do not skip.

  1. Internal validation — nested CV or bootstrap on the discovery cohort. Optimism-corrected.
  2. Internal-external — leave-one-site-out or leave-one-batch-out within the discovery dataset. Probes site/batch robustness.
  3. External validation — independent cohort, ideally collected by a different group, with pre-specified model and threshold (locked).
  4. Prospective validation — biomarker used in real time with outcomes assessed after. Required for most regulatory submissions.

A biomarker is not validated until step 3 at minimum, and the model + threshold were locked before seeing the external data. Re-tuning on external data = discovery, not validation.

Decision tree: which validation tier applies?

Start
│
├── Only one cohort available?
│     └── Internal validation only (nested CV + bootstrap optimism correction).
│         Label result as "discovery", not "validated".
│
├── Multi-site data within a single study?
│     └── Add internal-external (leave-one-site-out).
│         Report performance per site, not just pooled.
│
├── Truly independent cohort available?
│     └── Lock model + threshold → evaluate once → report with CIs.
│         Pre-register the analysis plan if possible.
│
└── Intended for clinical deployment / regulatory submission?
      └── Prospective validation on the target population,
          under intended-use conditions, with the locked model.

7. Sample Size and Events-Per-Variable

For Cox and logistic models: aim for 10–20 events per candidate variable considered during modeling (not just the final set). Counting only the selected variables after LASSO is a mistake — the selection itself used the full candidate pool.

In high-dimensional settings (omics, radiomics) events-per-variable is unattainable. Compensate with:

  • Penalization (LASSO/elastic net) or Bayesian shrinkage priors.
  • Stability selection to control false-discovery rate of selected features.
  • Optimism-corrected performance via bootstrap (.632+ or Harrell's bootstrap optimism correction).
  • Pre-specification of the number of features carried forward.

Event counts, not sample size, are the binding constraint for time-to-event outcomes. 1000 patients with 30 events ≈ a 30-event study.

8. Multi-Omics Integration

When combining transcriptomics + proteomics + imaging + clinical:

  • Early integration (concatenate all features, fit one model): high-dimensional, sensitive to scale differences and missing modalities. Works only with very large n.
  • Intermediate integration (MOFA, canonical correlation, kernel methods, shared latent factors): good when you want to find shared biology across layers. Moderate n.
  • Late integration (fit one model per omic, combine predictions via stacking or simple averaging): most robust when n is small, tolerates missing modalities per patient, and is easiest to validate modality-by-modality.

Default with small-to-moderate sample sizes: late integration. Escalate to intermediate or early only if n supports it and shared-factor interpretation is a goal.

Missing modalities are the norm, not the exception — design for it from the start.

9. Clinical Utility — The Decision Test

A biomarker with excellent AUC that does not change any decision is not useful. For every candidate, the agent should force the user to answer:

  • What decision does this biomarker change? (treat vs not, escalate vs de-escalate, biopsy vs observe, enroll vs exclude.)
  • At what threshold? Thresholds must be pre-specified and tied to the decision's costs and benefits.
  • What is the net benefit over treat-all and treat-none, across the plausible threshold range? Use decision curve analysis.
  • Who is harmed by a false positive or false negative, and at what rate is that acceptable?

If the user cannot answer these, clinical utility is undefined — regardless of AUC.

When NOT to Use This Skill

  • Established validated biomarkers already in clinical guidelines (e.g., HER2, BRCA1/2) — use guideline-concordant testing protocols instead
  • Clinical deployment or CLIA/CAP lab validation decisions — those require regulatory and laboratory expertise, not discovery methodology
  • Companion diagnostic development — that is a regulatory/manufacturing problem, not a biomarker discovery problem

When to Escalate to Human Expert

  • The biomarker will be used for treatment selection in a clinical trial — requires biostatistician sign-off on the adaptive design
  • Analytical validation (sensitivity, specificity, reproducibility across platforms) is needed — requires wet-lab expertise
  • Ethical review is needed for biomarker-driven patient stratification that could deny treatment to a subgroup

Common Mistakes

  • Wrong: Claiming a biomarker is "predictive" from a single-arm study Right: Require a comparator arm (RCT or emulated target trial) to estimate a treatment-by-biomarker interaction Why: Without a counterfactual arm, you cannot distinguish prognostic from predictive — the biomarker may simply mark prognosis regardless of treatment

  • Wrong: Performing feature selection on the full dataset, then running CV on the reduced feature set Right: Always perform feature selection inside the CV inner loop so each fold selects features independently Why: Selected features already "know" the test labels, inflating performance estimates and producing unreproducible models

  • Wrong: Splitting by row when a patient contributes multiple samples Right: Split at the patient level so all samples from one patient stay in the same fold Why: Repeated measures, bilateral lesions, and longitudinal labs leak patient identity across folds, inflating apparent performance

  • Wrong: Tuning the decision threshold on the test set Right: Lock thresholds on training data or pre-specify them based on clinical cost-benefit reasoning Why: Optimizing the threshold on test data overfits to the evaluation set and produces unreliable operating characteristics

  • Wrong: Reporting PPV/NPV from a 50/50 case-control sample and implying it generalizes Right: Re-estimate PPV and NPV at the deployment prevalence using Bayes' theorem Why: PPV and NPV are prevalence-dependent — values from enriched samples are misleading at real-world disease rates

  • Wrong: Ignoring calibration when reporting model performance Right: Always report calibration (calibration-in-the-large, calibration slope, calibration plots) alongside discrimination Why: Good discrimination with poor calibration produces clinically dangerous probability estimates that misinform decisions

  • Wrong: Counting events-per-variable only after feature selection Right: Count EPV against all candidate variables considered during modeling, not just the final selected set Why: The selection process itself used the full candidate pool — the effective degrees of freedom reflect the original dimensionality

  • Wrong: Declaring a biomarker "validated" based on cross-validation on the discovery cohort Right: Require external replication on an independent cohort with a locked model and pre-specified threshold Why: Cross-validation is internal validation only — it estimates optimism but does not prove generalizability

  • Wrong: Confounding the biomarker signal with site, batch, platform, or scanner effects Right: Always check whether site/batch predicts outcome as well as the biomarker does; include site as a covariate or use leave-one-site-out validation Why: If all cases come from one site and controls from another, the model learns site identity, not biology

  • Wrong: Using future information as a feature (e.g., a lab ordered because of clinical suspicion) Right: Define a clean time origin and only use data available before it Why: A lab ordered because of suspicion encodes the suspicion itself — this is temporal leakage, not predictive signal

  • Wrong: Early integration of multi-omics with small sample sizes Right: Use late integration (fit one model per omic, combine predictions via stacking) when n is small to moderate Why: Concatenating thousands of features across layers with a few hundred patients overfits to batch effects, not biology

  • Wrong: Reporting only point estimates without confidence intervals Right: Always include bootstrap or analytic confidence intervals for all performance metrics Why: Single numbers hide instability — a C-index of 0.78 with a 95% CI of [0.55, 0.92] tells a very different story

  • Wrong: Optimizing AUC while ignoring clinical utility Right: Perform decision curve analysis to demonstrate net benefit over treat-all and treat-none strategies Why: A 0.85 AUC that changes no clinical decision is worse than a 0.70 AUC that reliably changes one

  • Wrong: Retraining or tuning the model on external validation data "just a little" Right: Lock the model completely before seeing external data — any tuning collapses validation back into discovery Why: Even minor adjustments on external data eliminate its independence, making the "validation" circular

  • Wrong: Skipping decision curve analysis when reporting biomarker performance Right: Always include net-benefit curves across the plausible threshold range Why: Without net-benefit reasoning, there is no evidence the biomarker helps patients — only that it correlates with outcome

References

FAQ

What does the biomarker-discovery skill do?

Reason about biomarker discovery and validation in HCLS — classifying biomarker intent, choosing feature-selection and cross-validation strategies, avoiding leakage, and planning external replication. Use when the user asks to discover, develop, or validate a biomarker; select features from high-dimensional omics or clinical data; design a validation study; choose evaluation metrics; justify sample size; combine multi-omics signals; or assess clinical utility. Triggers include "discover a biomarker", "validate biomarker", "prognostic vs predictive", "feature selection", "LASSO vs elastic net", "nested cross-validation", "data leakage", "C-index", "time-dependent AUC", "decision curve analysis", "external validation cohort", "events per variable", "optimism-corrected", "multi-omics integration", "clinical utility of a biomarker", "is this biomarker ready".

How do I install biomarker-discovery?

Run npx skills add https://github.com/awslabs/hcls-agent-skills --skill biomarker-discovery in your project. The skills CLI detects the agents you use and copies the skill into the right folder. For Claude Code you can also place the skill folder at ~/.claude/skills/biomarker-discovery/ (personal) or .claude/skills/biomarker-discovery/ (project).

Which AI agents can use biomarker-discovery?

Any agent that supports the open Agent Skills format (a folder with a SKILL.md file), including Claude Code, Codex, Cursor, GitHub Copilot, Gemini CLI, Windsurf, Cline, OpenCode and more.

Is biomarker-discovery safe to install?

No partner security audit is available yet. Skills can run commands and scripts, so read the SKILL.md and any bundled files before installing.

Who maintains biomarker-discovery?

It is published by awslabs in awslabs/hcls-agent-skills. It has 82 recorded installs.

More from awslabs/hcls-agent-skills

View all →
awslabs avatar

ml-researcher

awslabs/hcls-agent-skills

Reason about ML experiment design for healthcare and life sciences data. Use when the user asks to design an ML study, choose a model for clinical/biomedical data, set up cross-validation, pick evaluation metrics, audit fairness, plan a regulatory submission, or critique an ML pipeline on EHR, medical imaging, genomics, molecules, or clinical text. Triggers include "design an ML experiment", "which model for this clinical data", "how should I split", "nested CV", "class imbalance", "AUROC vs AUPRC", "calibration", "decision curve", "net benefit", "TRIPOD+AI", "PROBAST", "CLAIM", "FDA SaMD", "PCCP", "GMLP", "site generalization", "temporal leakage", "scaffold split", "foundation model evaluation", "subgroup fairness", "is this model ready for deployment".

AI & Agents92 installs
awslabs avatar

clinical-data-standards

awslabs/hcls-agent-skills

Reason about clinical data terminology standards — MedDRA hierarchy (LLT→PT→HLT→HLGT→SOC), ICD-10 code structure and grouping, SNOMED CT concept model, LOINC panel relationships, and mapping decisions between systems. Use when the user asks to code adverse events, map diagnoses to ICD-10, choose a coding granularity level, group AEs by SOC or PT, interpret SNOMED CT relationships, select LOINC codes for lab panels, convert between terminology systems, or decide when to aggregate at HLT vs PT level. Triggers include "MedDRA coding", "ICD-10 grouping", "SNOMED CT", "LOINC panel", "adverse event coding", "terminology mapping", "SOC table", "preferred term", "code hierarchy", "clinical coding", "AE frequency table", "diagnosis grouping", "lab code selection", "cross-walk between terminologies".

AI & Agents91 installs
awslabs avatar

dicom-processing

awslabs/hcls-agent-skills

DICOM and NIfTI medical image processing pipeline. Triggers on DICOM, NIfTI, dcm2niix, de-identification, pydicom, DICOM header, conversion, anonymization, BIDS, DICOM tags, medical image format conversion, "DICOM to NIfTI", "burned-in PHI", "SeriesInstanceUID", "nibabel", "DICOM anonymization".

Marketing & SEO90 installs
awslabs avatar

radiology-preprocessing

awslabs/hcls-agent-skills

Structural MRI/CT preprocessing pipeline for radiology workflows covering skull stripping, bias field correction, registration, and intensity normalization. Triggers on skull stripping, bias correction, registration, ANTs, FSL, HD-BET, N4, brain extraction, normalization, FLIRT, FNIRT, SyN, fslreorient2std, MNI registration, T1 preprocessing.

AI & Agents89 installs
awslabs avatar

medical-device-software-compliance

awslabs/hcls-agent-skills

Reason about SaMD (Software as a Medical Device) regulatory compliance for FDA, EU MDR, and global submissions. Use when the user asks about IEC 62304 safety classification, ISO 14971 risk management, 21 CFR 820/QMSR quality system requirements, Design History File structure, 510(k)/De Novo/PMA pathway selection, SOUP/OTS assessment, verification and validation planning, cybersecurity for medical devices, PCCP for AI/ML devices, design reviews, traceability matrices, or post-market surveillance. Triggers include "SaMD", "medical device software", "IEC 62304", "ISO 14971", "ISO 13485", "21 CFR 820", "QMSR", "510(k)", "De Novo", "PMA", "design history file", "DHF", "software safety classification", "SOUP list", "risk management", "hazard analysis", "design review", "V&V protocol", "FDA submission", "EU MDR", "clinical evaluation", "PCCP", "predetermined change control", "GMLP", "cybersecurity premarket", "Part 11", "design controls", "design inputs", "design outputs", "traceability matri

awslabs avatar

ehr-data-parsing

awslabs/hcls-agent-skills

Parse and extract clinical data from HL7v2 messages and FHIR R4 resources using Python. Use when the user mentions HL7v2, HL7, FHIR, PID segment, OBX segment, MSH segment, Patient resource, Observation resource, Condition resource, MedicationRequest, EHR data extraction, clinical message parsing, FHIR bundle, HL7 to FHIR conversion, ADT message, ORU message, lab result extraction, or clinical data quality checks. Triggers include "parse HL7", "extract FHIR", "HL7v2 message", "FHIR resource", "PID segment", "OBX segment", "Patient resource", "Observation resource", "EHR parsing", "clinical data extraction", "HL7 to CSV", "FHIR to DataFrame".

Data & Databases88 installs

Popular ai & agents skills

View category →
google avatar

google-agents-cli-publish

google/agents-cli

This skill should be used when the user wants to "publish an agent", "publish my ADK agent", "register an agent with Gemini", "publish to Gemini" (formerly Gemini Enterprise), or needs guidance on the agents-cli publish gemini command. Also use when the user wants to "manage agents in Agent Registry", "list/update/delete registered agents", or "register an MCP server". Covers ADK vs A2A registration modes, programmatic and interactive usage, flag reference, auto-detection from deployment metadata, Agent Registry fleet management, and troubleshooting. Part of the agents-cli skills suite. Do NOT use for deployment (use google-agents-cli-deploy).

AI & Agents588.1K installs
google avatar

google-agents-cli-eval

google/agents-cli

This skill should be used when the user wants to "run an evaluation", "evaluate my agent", "evaluate my ADK agent", "write an eval dataset", "analyze eval failures", "compare eval results", "optimize agent", or needs guidance on the Gemini platform eval methodology and the Quality Flywheel. Covers eval metrics, dataset schema, LLM-as-judge scoring, and common failure causes. Applies to any agents-cli project, whatever framework the agent is written in. Do NOT use for agent API code patterns (ADK: use google-agents-cli-adk-code), deployment (use google-agents-cli-deploy), or project scaffolding (use google-agents-cli-scaffold).

AI & Agents586.9K installs
anthropics avatar

skill-creator

anthropics/skills

Create new skills, modify and improve existing skills, and measure skill performance. Use when users want to create a skill from scratch, edit, or optimize an existing skill, run evals to test a skill, benchmark skill performance with variance analysis, or optimize a skill's description for better triggering accuracy.

OfficialAI & Agents439.1K installs
prime-skills avatar

codex-pet

prime-skills/runcomfy-agent-skills

Codex Pet generator on RunComfy. Build a Codex-compatible Codex Pet spritesheet.webp + pet.json from a single reference image, drop it into ${CODEXHOME:-$HOME/.codex}/pets/ / and Codex picks it up as a custom Codex Pet next to the 8 built-ins. This skill produces the exact Codex Pet atlas Codex expects (1536x1872 PNG/WebP, 8 cols x 9 rows, 192x208 cells, 9 animation states — idle, running-right, running-left, waving, jumping, failed, waiting, running, review). Calls OpenAI GPT Image 2 edit ONCE via the local RunComfy CLI as runcomfy run openai/gpt-image-2/edit to produce a canonical Codex Pet pose, then assembles all 9 animation rows programmatically with ImageMagick micro-transforms — no Codex Pro, no $imagegen, no OPENAIAPIKEY required, only RUNCOMFYTOKEN. Triggers on "codex pet", "create codex pet", "make codex pet", "hatch codex pet", "/hatch image", "desktop pet codex", "codex pets", "spritesheet.webp", or any explicit ask to build a custom pet for OpenAI Codex.

AI & Agents413K installs
leonxlnx avatar

full-output-enforcement

leonxlnx/taste-skill

Overrides default LLM truncation behavior. Enforces complete code generation, bans placeholder patterns, and handles token-limit splits cleanly. Apply to any task requiring exhaustive, unabridged output.

AI & Agents401.1K installs
obra avatar

executing-plans

obra/superpowers

Use when executing an implementation plan in the current session as the implementer yourself — your human partner chose inline execution, or no subagent tool is available

AI & Agents269.7K installs