MCPInstall
matlab avatar

simulink-frequency-response

Estimate frequency response from Simulink models using frestimate. Use when frequency response should be obtained from simulation rather than model linearization.

Installs
0
Last 24h
—
Trending rank
—
Security
Not audited

Install

Works with every agent the skills CLI supports.

npx skills add https://github.com/matlab/simulink-agentic-toolkit --skill simulink-frequency-response
  1. 01

    Install

    Run the command in your project. The CLI asks which agents to install for.

  2. 02

    Describe the task

    Ask your agent for something this skill covers. It loads simulink-frequency-response automatically when relevant.

  3. 03

    Review the result

    The agent follows the SKILL.md steps, scripts and references bundled with the skill.

SKILL.md

The instructions your agent reads when the skill is triggered.

Simulink Frequency Response Estimation

Obtain frequency response data from Simulink models using simulation-based estimation (frestimate) when analytical linearization is not viable or as a validation tool.

When to Use

  • Model contains hard discontinuities (PWM, switching, relay, quantizer) that linearize to zero or NaN
  • Validating a linear model against a simulation based linearization of a Simulink model
  • Estimating frequency response directly from simulation data

When NOT to Use

  • Model linearizes cleanly with linearize — use simulink-linearize instead
  • Working with measured data only (no Simulink model) — use System Identification Toolbox

Workflow

1. Define I/O  →  2. Choose Signal  →  3. Configure  →  4. Estimate  →  5. Fit (optional)
   (linio)          (PRBS/Sinestream)    (constraints)    (frestimate)     (tfest)

Stage 1: Define I/O Points

Determine I/O points for the estimation using this decision sequence. Use the first case that applies:

Case A — IO points can be inferred from prompt or model context:

Use the first sub-case that matches:

  1. User specifies explicit I/O signals or blocks (e.g., "from r to y") → define linio points. All linio points must reference a block's output port. If a candidate block has no output ports (Outport, Terminator, Scope) → trace upstream to find the source block and port with model_read.

    io = [linio(sprintf("%s/InputBlock", mdl), 1, "input"); ...
          linio(sprintf("%s/OutputBlock", mdl), 1, "output")];
    
  2. Root-level Inport/Outport blocks exist → use model_read at root scope (depth "0") to identify root-level Inport/Outport blocks, then define linio at those blocks (trace Outport blocks upstream to their source for the output linio point).

Case B — Cannot determine IO points:

If none of the above apply → do not guess. Ask the user which signals to use as estimation input and output. Present the available blocks/signals from the model to help them decide.

Pre-flight checks (before choosing a signal):

  1. Verify I/O points are NOT at blocks without output ports (Outport, Terminator, Scope)
  2. Check sample times at I/O points — both must match the perturbation signal rate, or both must be continuous
  3. Consider whether the model has time-varying source blocks (Step, Ramp, Signal Generator, etc.) that could drive the system away from its steady-state operating point during estimation. If so, see Disabling Time-Varying Sources below.

Stage 2: Choose Perturbation Signal

Decision (follow in order):

  1. Is broadband estimation sufficient (most cases)? → Use frest.PRBS (DEFAULT)
  2. Is the model discrete? → Use frest.PRBS with Ts matching the I/O sample time, or frest.createFixedTsSinestream if per-frequency data needed
  3. Do you need precise magnitude/phase at specific frequencies? → Use frest.Sinestream (continuous) or frest.createFixedTsSinestream (discrete)

Prefer frest.PRBS — it estimates the full frequency range in a single simulation. Sinestream simulates each frequency sequentially and is significantly slower for broadband estimation.

Stage 3: Configure the Signal

PRBS (default):

in = frest.PRBS(Ts=Ts, Amplitude=0.01, Order=10, NumPeriods=2);

If the I/O signal is discrete, set Ts to match the signal sample time. If continuous, set Ts to a value that provides sufficient temporal resolution. Choose Amplitude small enough to stay in the linear regime of saturations/nonlinearities.

Why PRBS first? A single PRBS simulation estimates the full frequency range at once. Sinestream simulates each frequency sequentially — for 30 frequencies with 8 periods each, this can take 10-100x longer. Use Sinestream only when you need precise per-frequency data (e.g., gain/phase margin at specific crossover frequencies).

Sinestream (continuous models):

in = frest.Sinestream(Frequency=logspace(-1, 2, 30), Amplitude=0.01);
in.NumPeriods = 8;
in.SettlingPeriods = 3;

The filtering constraint: NumPeriods - SettlingPeriods >= 3 when ApplyFilteringInFRESTIMATE = "on" (default). Violating this throws an error at estimation time.

Fixed-Ts Sinestream (discrete models):

Ts = 0.01;
in = frest.createFixedTsSinestream(Ts, {wmin, wmax});
in.Amplitude = 0.01;
in.NumPeriods = 8;
in.SettlingPeriods = 3;

Use the cell syntax {wmin, wmax} for the frequency range — this auto-selects frequencies that are valid integer divisors of the sampling frequency. Do NOT pass an explicit frequency vector:

% CORRECT — cell syntax auto-selects valid frequencies
in = frest.createFixedTsSinestream(Ts, {wmin, wmax});

% WRONG — explicit vector (most frequencies violate integer-multiple constraint)
in = frest.createFixedTsSinestream(Ts, logspace(-1, 2, 30));  % Error

When to use Sinestream instead of PRBS:

  • PRBS results are too noisy (high variance at individual frequencies)
  • Need precise magnitude/phase at specific frequencies
  • Very nonlinear system where broadband excitation causes intermodulation

Check simulation time: Always verify that the signal duration is practical before launching the estimation:

tFinal = getSimulationTime(in);
fprintf("Estimated simulation time: %.1f seconds\n", tFinal);

If tFinal is too big compared to Ts, use larger lower frequency bounds for estimation.

Stage 4: Estimate

Determine where to start the experiment. Choose one:

SituationApproach
Model ICsSkip — frestimate uses model initial conditions
Steady-state trimoperspec → configure → findop
Need snapshot from simulationfindop(mdl, tSnapshot)
Operating point knownoperpoint object → configure
sysest = frestimate(mdl, op, io, in, opts);

op and opts are optional arguments. If op is not provided, the experiment will start at model initial conditions.

opts is a frestimateOptions object. Pass it when time-varying sources need to be disabled (see below).

The result is an frd (frequency response data) object.

Stage 5: Fit Parametric Model (Optional)

Only perform this step if a parametric model (transfer function, state-space, zpk) is required. If the goal is frequency response data only (e.g., Bode plot, gain/phase margins from frd), stop after Stage 4.

Convert the non-parametric frd to a parametric model:

sysFit = tfest(sysest, np, nz);
fprintf("Fit: %.1f%%\n", sysFit.Report.Fit.FitPercent);

Disabling Time-Varying Sources

Time-varying source blocks (Step, Ramp, Signal Generator, etc.) can drive the model away from its steady-state operating point during estimation. When this happens, the system does not remain near the operating point and the estimated response is unreliable — gain estimates can be off by orders of magnitude while executing without error.

When to disable sources:

  • The model contains source blocks (other than the perturbation input) that change value during the estimation simulation
  • Estimation results are implausible or don't match an expected linearization
  • The time-domain response does not reach steady state at individual frequencies

How to identify and disable them:

Use frest.findSources to identify time-varying source blocks in the estimation path, then set BlocksToHoldConstant so they are held at their initial value during estimation:

srcblks = frest.findSources(mdl, io);
opts = frestimateOptions;
opts.BlocksToHoldConstant = srcblks;
sysest = frestimate(mdl, io, in, opts);

Note: frest.findSources requires model compilation. The perturbation input is not affected by BlocksToHoldConstant.

The Fallback Pattern

When linearize returns zero, follow this sequence:

% 1. Try linearize
sys = linearize(mdl, io);
if dcgain(sys) == 0
    % 2. Disable time-varying sources if present
    srcblks = frest.findSources(mdl, io);
    opts = frestimateOptions;
    opts.BlocksToHoldConstant = srcblks;
    % 3. Fall back to frestimate with PRBS
    in = frest.PRBS(Ts=Ts, Amplitude=0.01, Order=10, NumPeriods=2);
    sysest = frestimate(mdl, io, in, opts);
    % 4. Fit parametric model
    sysFit = tfest(sysest, 2);
end

Do NOT use manual block substitution (replace_block) as a workaround for zero linearization. The frestimate approach is generalizable to any discontinuous model without requiring domain knowledge of each block's averaged equivalent.

Key Functions

FunctionPurposeAvailable From
frestimateEstimate frequency response from SimulinkR2009b
frest.findSourcesIdentify time-varying source blocks to hold constantR2010b
frestimateOptionsOptions including BlocksToHoldConstantR2010a
frest.PRBSPseudorandom binary sequence signalR2020a
frest.SinestreamMulti-sine perturbation signalR2009b
frest.createFixedTsSinestreamFixed sample time sinestreamR2009b
getSimulationTimeCheck signal duration before runningR2012a
tfestFit transfer function to frequency dataR2012a
ssestFit state-space model to frequency dataR2012a

Common Mistakes

MistakeWhy It FailsCorrect Approach
Not disabling time-varying sourcesSource blocks drive the model away from its steady-state operating point, producing unreliable estimates without errorUse frest.findSources to identify sources, set opts.BlocksToHoldConstant to disable them
Using replace_block to work around zero linearizationRequires domain knowledge of averaged equivalents; doesn't generalizeUse frestimate with PRBS — works for any discontinuous model
Setting NumPeriods=5, SettlingPeriods=3 with filtering onViolates NumPeriods - SettlingPeriods >= 3 constraintUse NumPeriods=8, SettlingPeriods=3 or disable filtering
Output linio at different rate than input signalfrestimate rejects multi-rate I/O configurationsPlace both I/O points at blocks matching the signal's sample time
Only using frest.Sinestream (ignoring PRBS)Sinestream is much slower — simulates each frequency sequentiallyStart with frest.PRBS for broadband estimation; use Sinestream only when frequency-by-frequency precision is needed
Large perturbation amplitude near saturationsDrives system into nonlinear regime, corrupting estimationChoose amplitude small relative to saturation limits (e.g., 1-5% of range)

Conventions

  • Always: Consider whether time-varying sources could drive the model from its operating point — use frest.findSources and BlocksToHoldConstant to disable them
  • Prefer: frest.PRBS for broadband estimation — faster than Sinestream for most workflows
  • Always: Use cell syntax {wmin, wmax} with frest.createFixedTsSinestream
  • Always: Ensure NumPeriods - SettlingPeriods >= 3 when filtering is enabled
  • Always: Place I/O points at rate-compatible blocks for multi-rate models
  • Always: Call getSimulationTime — Validate signal duration before running. Long simulations relative to max solver step size should prompt redesign.
  • Prefer: frestimate over manual block substitution for discontinuous models
  • Prefer: tfest or ssest for fitting parametric models to frd results
  • Prefer: Small amplitude — Keep perturbation small enough to stay in the locally linear regime (typically 1-5% of operating range).
  • Never: Use replace_block as a general linearization workaround

Copyright 2026 The MathWorks, Inc.


FAQ

What does the simulink-frequency-response skill do?

Estimate frequency response from Simulink models using frestimate. Use when frequency response should be obtained from simulation rather than model linearization.

How do I install simulink-frequency-response?

Run npx skills add https://github.com/matlab/simulink-agentic-toolkit --skill simulink-frequency-response in your project. The skills CLI detects the agents you use and copies the skill into the right folder. For Claude Code you can also place the skill folder at ~/.claude/skills/simulink-frequency-response/ (personal) or .claude/skills/simulink-frequency-response/ (project).

Which AI agents can use simulink-frequency-response?

Any agent that supports the open Agent Skills format (a folder with a SKILL.md file), including Claude Code, Codex, Cursor, GitHub Copilot, Gemini CLI, Windsurf, Cline, OpenCode and more.

Is simulink-frequency-response safe to install?

No partner security audit is available yet. Skills can run commands and scripts, so read the SKILL.md and any bundled files before installing.

Who maintains simulink-frequency-response?

It is published by matlab in matlab/simulink-agentic-toolkit. It has 0 recorded installs.

More from matlab/simulink-agentic-toolkit

View all →
matlab avatar

building-simulink-models

matlab/simulink-agentic-toolkit

Builds and edits Simulink, System Composer, Stateflow, and Simscape models. Use when modifying model structure, parameters, ports, connections, or Stateflow chart internals.

AI & Agents185 installs
matlab avatar

simulating-simulink-models

matlab/simulink-agentic-toolkit

Configures Simulink simulations non-destructively using SimulationInput objects — parameter overrides without modifying the model, batch sweeps via parsim, custom input signals via Dataset, and simulation data retrieval via logsout. Use when running sim()/parsim() with setVariable, setBlockParameter, setExternalInput, or when performing parameter sweeps and multi-run analysis. Not needed for one-shot simulations without configuration.

Data & Databases156 installs
matlab avatar

testing-simulink-models

matlab/simulink-agentic-toolkit

Tests Simulink models using either ephemeral Gherkin-based tests (modeltest) for quick validation or persistent tests (Simulink Test API) authored from requirements or behavioral specs. Requires Simulink Test.

Testing & QA124 installs
matlab avatar

specifying-plant-models

matlab/simulink-agentic-toolkit

Specify plant models for closed-loop simulation: system specs, architecture, build plans, validation plans. Use when creating, updating, or reviewing plant model specifications, planning plant model architecture, or planning plant model validation.

matlab avatar

specifying-mbd-algorithms

matlab/simulink-agentic-toolkit

Specify algorithms for Model-Based Design: system specs, architecture specs, implementation plans, test plans. Use when creating specifications for controllers, signal processing, diagnostics, estimators, or other algorithms authored in Simulink, Stateflow, System Composer, or MATLAB Function blocks.

AI & Agents90 installs
matlab avatar

generate-requirement-drafts

matlab/simulink-agentic-toolkit

Generates draft requirements from Simulink models. Use when drafting or updating requirement artifacts from a model. Prefers Requirements Toolbox (.slreqx) when available; falls back to structured YAML.

AI & Agents80 installs

Popular ai & agents skills

View category →
google avatar

google-agents-cli-publish

google/agents-cli

This skill should be used when the user wants to "publish an agent", "publish my ADK agent", "register an agent with Gemini", "publish to Gemini" (formerly Gemini Enterprise), or needs guidance on the agents-cli publish gemini command. Also use when the user wants to "manage agents in Agent Registry", "list/update/delete registered agents", or "register an MCP server". Covers ADK vs A2A registration modes, programmatic and interactive usage, flag reference, auto-detection from deployment metadata, Agent Registry fleet management, and troubleshooting. Part of the agents-cli skills suite. Do NOT use for deployment (use google-agents-cli-deploy).

AI & Agents588.1K installs
google avatar

google-agents-cli-eval

google/agents-cli

This skill should be used when the user wants to "run an evaluation", "evaluate my agent", "evaluate my ADK agent", "write an eval dataset", "analyze eval failures", "compare eval results", "optimize agent", or needs guidance on the Gemini platform eval methodology and the Quality Flywheel. Covers eval metrics, dataset schema, LLM-as-judge scoring, and common failure causes. Applies to any agents-cli project, whatever framework the agent is written in. Do NOT use for agent API code patterns (ADK: use google-agents-cli-adk-code), deployment (use google-agents-cli-deploy), or project scaffolding (use google-agents-cli-scaffold).

AI & Agents586.9K installs
anthropics avatar

skill-creator

anthropics/skills

Create new skills, modify and improve existing skills, and measure skill performance. Use when users want to create a skill from scratch, edit, or optimize an existing skill, run evals to test a skill, benchmark skill performance with variance analysis, or optimize a skill's description for better triggering accuracy.

OfficialAI & Agents439.1K installs
prime-skills avatar

codex-pet

prime-skills/runcomfy-agent-skills

Codex Pet generator on RunComfy. Build a Codex-compatible Codex Pet spritesheet.webp + pet.json from a single reference image, drop it into ${CODEXHOME:-$HOME/.codex}/pets/ / and Codex picks it up as a custom Codex Pet next to the 8 built-ins. This skill produces the exact Codex Pet atlas Codex expects (1536x1872 PNG/WebP, 8 cols x 9 rows, 192x208 cells, 9 animation states — idle, running-right, running-left, waving, jumping, failed, waiting, running, review). Calls OpenAI GPT Image 2 edit ONCE via the local RunComfy CLI as runcomfy run openai/gpt-image-2/edit to produce a canonical Codex Pet pose, then assembles all 9 animation rows programmatically with ImageMagick micro-transforms — no Codex Pro, no $imagegen, no OPENAIAPIKEY required, only RUNCOMFYTOKEN. Triggers on "codex pet", "create codex pet", "make codex pet", "hatch codex pet", "/hatch image", "desktop pet codex", "codex pets", "spritesheet.webp", or any explicit ask to build a custom pet for OpenAI Codex.

AI & Agents413K installs
leonxlnx avatar

full-output-enforcement

leonxlnx/taste-skill

Overrides default LLM truncation behavior. Enforces complete code generation, bans placeholder patterns, and handles token-limit splits cleanly. Apply to any task requiring exhaustive, unabridged output.

AI & Agents401.1K installs
obra avatar

executing-plans

obra/superpowers

Use when executing an implementation plan in the current session as the implementer yourself — your human partner chose inline execution, or no subagent tool is available

AI & Agents269.7K installs