MCPInstall
matlab avatar

create-sdi-run

Import data into the Simulation Data Inspector (SDI) from MAT, CSV, or Excel files, from workspace variables, or from a Simulink simulation. Use when the user wants to view a logged file in SDI, load a bench-test log, or verify what a just-completed Simulink.sdi.createRun or sim(model) produced. Covers the 'file', 'vars', and 'namevalue' sources of createRun, the auto-populate behavior after sim(), and post-import verification. Not for comparing existing runs (use Simulink.sdi.compareRuns); not for streaming data live during a running simulation (use Simulink.sdi.createRunOrAddToStreamedRun — a separate API); and not for authoring Gherkin or Simulink Test test cases, assertions, or regression tests (use testing-simulink-models). Do not activate on test-authoring or verification prompts even when no test-authoring skill is available — say so and stop.

Installs
0
Last 24h
—
Trending rank
—
Security
Not audited

Install

Works with every agent the skills CLI supports.

npx skills add https://github.com/matlab/simulink-agentic-toolkit --skill create-sdi-run
  1. 01

    Install

    Run the command in your project. The CLI asks which agents to install for.

  2. 02

    Describe the task

    Ask your agent for something this skill covers. It loads create-sdi-run automatically when relevant.

  3. 03

    Review the result

    The agent follows the SKILL.md steps, scripts and references bundled with the skill.

SKILL.md

The instructions your agent reads when the skill is triggered.

Create SDI Run

Get data into the Simulation Data Inspector using the shortest path that works. Most agents reflexively read files into the workspace and rebuild signals by hand; this skill teaches the direct paths and when each applies.

When to Use

  • User has a .mat, .csv, or .xlsx file of logged data and wants to view it in SDI.
  • User just ran sim(model) and wants to see the logged signals.
  • User has timeseries, timetable, or Simulink.SimulationData.Dataset variables in the workspace and wants an SDI run.
  • User asks about Simulink.sdi.createRun, Simulink.sdi.getAllRunIDs, or Simulink.sdi.getRun.

When NOT to Use

  • Comparing two existing runs — that is a distinct workflow (Simulink.sdi.compareRuns).
  • Streaming data live during a running simulation — this is a separate API (Simulink.sdi.createRunOrAddToStreamedRun), not a mode of createRun. Prompts like "stream data into SDI while my sim is running" belong to that API. Do not activate on those.
  • Files in MDF (.mf4), ULG, ROS bag, CAN log, or HDF5 formats — see references/format-support.md for what SDI reads natively vs. what needs a different toolbox.
  • Customizing plot layout, cursors, or subplot arrangement beyond opening the SDI window.
  • Authoring Gherkin .feature files, Simulink Test cases, matlab.unittest classes, or any pass/fail assertions or regression tests for a model or subsystem — use testing-simulink-models (Gherkin-based model_test, requires Simulink Test). Prompts like "write a Gherkin test for X", "verify abs(-5) equals 5", "create a regression test for this subsystem", or any request whose deliverable is a test artifact belong there. Do not activate this skill on such prompts even when testing-simulink-models is unavailable — in that case, tell the user which skill is missing and stop.

Workflow

Answer these four questions in order. The first "yes" tells you what to do.

1. Is the data already in SDI?

After sim(model) with signal logging enabled, SDI auto-populates one run. Do not call createRun — that produces a duplicate.

before = Simulink.sdi.getAllRunIDs;
simOut = sim("myModel");
after  = Simulink.sdi.getAllRunIDs;
if numel(after) > numel(before)
    Simulink.sdi.view;   % done — just open the window
end

If no new run appeared, logging is off. Enable it via the Simulink Agentic Toolkit model_edit tool with a configure op setting DataLogging on the target port, then re-simulate — or fall back to Step 3 with simOut. As a last resort, ask the user to right-click a signal → Log Selected Signals in the Simulink editor themselves; that step is for the user to perform, not the agent.

2. Is the data in a file?

Use the 'file' source. One call handles MAT, CSV, and Excel natively — no load, no readtable, no sheetnames loop.

runID = Simulink.sdi.createRun("bench_test","file","logs/bench_test.mat");

Excel with N sheets returns a 1×N int32 vector — one run ID per sheet. All returned runs inherit the base name; if the user needs sheet-named runs, rename each run in place with sheetnames() — do not delete and re-import per sheet:

runIDs = Simulink.sdi.createRun("cases","file","cases.xlsx");   % [id1, id2, ...]
sheets = sheetnames("cases.xlsx");
for k = 1:numel(runIDs)
    Simulink.sdi.getRun(runIDs(k)).Name = sheets(k);
end

Time-column header rule (CSV and Excel). SDI's built-in reader requires the time column to be named literally time (case-insensitive). Headers like time_s, t, Time (s), Timestamp cause SDI:sdi:ImportError. Try 'file' first and catch the error — do not pre-inspect the header row and guess, because SDI's matching rules can differ from your interpretation. On SDI:sdi:ImportError, fall back to the readmatrix + array2timetable + 'vars' pattern (Step 3 / CSV pattern below). Do not rewrite the source file.

Other createRun failures. createRun can also throw for reasons this skill does not enumerate — corrupted files, unsupported data types inside a MAT/Excel, malformed structs, permission errors, unregistered custom readers. When you catch an error identifier that is not SDI:sdi:ImportError, do not invent a fix or silently retry. Surface the full error identifier and message to the user, list the file or variables involved, and suggest they inspect the source (e.g., whos("-file",path) for a MAT, or sheetnames(path) plus a per-sheet read for an Excel). Ask before attempting an alternative import path.

3. Is the data in workspace variables?

Two sources, different purposes:

  • 'vars' — pass variables whose names or .Name properties are already correct. This is the default.
  • 'namevalue' — pass explicit signal names when the variables have no .Name metadata (e.g., bare arrays or unnamed timeseries).

Timeseries whose .Name is already what you want:

% TEMPLATE — not executable
runID = Simulink.sdi.createRun("baseline","vars", speedTS, torqueTS);

Timetable — signals inherit the column names:

% TEMPLATE — not executable
runID = Simulink.sdi.createRun("baseline","vars", benchTT);

Bare arrays needing explicit names:

% TEMPLATE — not executable
runID = Simulink.sdi.createRun("baseline","namevalue", ...
    {"velocity","load"}, {velocityData, loadData});

Gotcha (Gap E): if a timeseries passed to 'namevalue' has its own .Name set, .Name wins over the caller-supplied name. To force the name you want, either set ts.Name first and use 'vars', or clear it before 'namevalue'.

4. Verify the run

After every createRun or auto-populate:

ids = Simulink.sdi.getAllRunIDs;
run = Simulink.sdi.getRun(ids(end));
fprintf("Run %d: %s (%d signals)\n", ids(end), run.Name, run.SignalCount);
for k = 1:run.SignalCount
    fprintf("  %s\n", run.getSignalByIndex(k).Name);
end
Simulink.sdi.view;

Verify against MATLAB via the MATLAB MCP server's evaluate_matlab_code tool. If SignalCount == 0, the import silently produced nothing — investigate the source, do not report success.

Key Functions

All available from R2023a with base Simulink; no additional toolbox required.

FunctionPurposeAvailable From
Simulink.sdi.createRun(name)Empty run — used with Run.add for a per-signal build; rarely the right first choice.R2011b
Simulink.sdi.createRun(name,"file",path)Import a .mat, .csv, or .xlsx file. Returns scalar int32 for MAT/CSV, 1×N int32 vector for N-sheet Excel.R2011b
Simulink.sdi.createRun(name,"vars",v1,v2,...)Import workspace variables whose names/.Name are correct.R2011b
Simulink.sdi.createRun(name,"namevalue",names,values)Import with explicit names. See Gap E caveat.R2011b
Simulink.sdi.viewOpen the SDI window. Safe to call repeatedly; opens only if not visible.R2011b
Simulink.sdi.getAllRunIDsReturn int32 vector of every run's ID. Use before/after sim to detect auto-populate.R2017a
Simulink.sdi.getRun(runID)Return the Simulink.sdi.Run object for a run ID.R2011b
Simulink.sdi.clearDelete all SDI runs. Ask the user first — destructive.R2011b

Four createRun sources exist: empty, 'vars', 'namevalue', 'file'. When unsure, run help Simulink.sdi.createRun.

Patterns

Pattern: MAT file → SDI (one line)

runID = Simulink.sdi.createRun("sensor_log","file","data/sensor_log.mat");
Simulink.sdi.view;

The variables inside the MAT file may be timeseries, timetable, Simulink.SimulationData.Dataset, or legacy struct-with-time — SDI's reader picks them up automatically.

Pattern: CSV file → SDI (try 'file', catch, fall back)

Attempt the one-liner first. On SDI:sdi:ImportError, fall back to the timetable path — do not rewrite the file:

try
    runID = Simulink.sdi.createRun("bench_run","file","logs/bench_run.csv");
catch ME
    if strcmp(ME.identifier,"SDI:sdi:ImportError")
        raw     = readmatrix("logs/bench_run.csv");
        headers = string(readcell("logs/bench_run.csv","Range","1:1"));
        tt = array2timetable(raw(:,2:end), ...
                "RowTimes", seconds(raw(:,1)), ...
                "VariableNames", headers(2:end));
        runID = Simulink.sdi.createRun("bench_run","vars", tt);
    else
        rethrow(ME);
    end
end

Assumes the time column is column 1 and expressed in seconds — the common case for bench logs. If the time column sits elsewhere or uses different units, adjust the index or wrap it with the appropriate duration constructor (milliseconds, minutes, …) before passing to RowTimes.

Pattern: Excel with multiple sheets → one run per sheet

One createRun call per file. Every returned run initially inherits the base name you supplied — SDI does not auto-apply sheet names. Rename in place with sheetnames(); do not delete and re-import per sheet. The same time-column-header rule applies as for CSV — if a sheet's time column is not named time, createRun throws SDI:sdi:ImportError; wrap this call in the same try-then-fallback shown in the CSV pattern, using readmatrix(...,"Sheet",sheets(k)) and readcell(...,"Sheet",sheets(k),"Range","1:1") per sheet.

runIDs = Simulink.sdi.createRun("test_matrix","file","data/two_runs.xlsx");
% runIDs is a 1xN int32 vector — one ID per sheet, all named "test_matrix".
sheets = sheetnames("data/two_runs.xlsx");
for k = 1:numel(runIDs)
    run = Simulink.sdi.getRun(runIDs(k));
    run.Name = sheets(k);   % rename in place to the sheet name
    fprintf("Sheet run: %s (%d signals)\n", run.Name, run.SignalCount);
end

To restrict to specific sheets, use the sheets name-value — the returned vector is trimmed accordingly:

runIDs = Simulink.sdi.createRun("cases","file","cases.xlsx", ...
    sheets=["baseline","variant"]);

Pattern: Post-sim — just open SDI

before = Simulink.sdi.getAllRunIDs;
simOut = sim("controller_test");
after  = Simulink.sdi.getAllRunIDs;

if numel(after) > numel(before)
    Simulink.sdi.view;             % logged signals already imported
else
    % No auto-populate — logging is off. Enable it and re-simulate, or
    % pass simOut through createRun as a fallback:
    Simulink.sdi.createRun("run_from_simout","vars", simOut);
    Simulink.sdi.view;
end

Pattern: Rename workspace signals

Set .Name before 'vars'. This avoids the 'namevalue' override trap.

data = load("data/speed_torque.mat");
speed  = data.speed;
torque = data.torque;
speed.Name  = "velocity";
torque.Name = "torqueNm";
runID = Simulink.sdi.createRun("baseline","vars", speed, torque);

Conventions

Always

  • Check whether SDI already has the data before calling createRun. Use Simulink.sdi.getAllRunIDs before and after sim(model). If a new run appeared, sim already imported the logged signals — call Simulink.sdi.view and stop.
  • Prefer the 'file' source for .mat, .csv, .xlsx. It handles the read and the signal-naming for you. Reserve load/readtable/sheetnames for the CSV time-column fallback and for genuinely workspace-first workflows.
  • Verify with SignalCount. After every import, confirm at least one signal exists. Zero signals means the import failed silently.
  • Read help Simulink.sdi.createRun if you are unsure which source applies. The four sources are the entire API surface for import.

Ask First

  • Simulink.sdi.clear — deletes every run. Confirm with the user before running.
  • Modifying the source file (e.g., renaming a CSV column to time) — prefer the timetable fallback pattern instead of altering user data.
  • Attempting an alternative import path after a non-SDI:sdi:ImportError failure — surface the error to the user first, then ask which path they want.

Never

  • Never invent function names. Simulink.sdi.createRunFromFile does not exist. Use Simulink.sdi.createRun(name,"file",path).
  • Never rebuild a file-side workflow through load / readtable / manual timeseries construction / Run.add when the 'file' source handles the same file natively.
  • Never assume namevalue names take precedence over timeseries.Name — .Name wins. See Gap E in Common Mistakes.
  • Never claim success without inspecting SignalCount and the signal names.

Common Mistakes

MistakeWhy It's WrongCorrect Approach
Reading MAT/CSV/Excel yourself and calling createRun(...,"vars",...)Duplicates the 'file' source's work; loses SDI's automatic signal-name handling; scales badly for multi-sheet Excel.Simulink.sdi.createRun(name,"file",path).
Deleting the multi-sheet import and re-calling createRun in a per-sheet loop because both runs share the base nameDiscards the correct one-call 'file' import and violates the "single call handles sheet expansion" convention. All runs from one Excel file inherit the base name — they are not auto-renamed to sheet names.Keep the one createRun(...,"file",xlsx) call and rename each run in place: Simulink.sdi.getRun(runIDs(k)).Name = sheets(k).
Calling createRun(...,"namevalue",{"SimOut"},{simOut}) after sim(model)With signal logging on, sim already imported the run. This adds a duplicate.sim(model); Simulink.sdi.view; (verify with getAllRunIDs before/after).
Using Simulink.sdi.createRunFromFileFunction does not exist. Hallucination.Simulink.sdi.createRun(name,"file",path).
Passing namevalue names when the timeseries has its own .Name.Name overrides the caller-supplied name silently — Gap E.Set ts.Name first, then use 'vars'. Or clear .Name before 'namevalue'.
Pre-inspecting the header and skipping 'file' because you think the time column is misnamedYour guess can differ from SDI's actual matching rules; skipping 'file' costs the automatic signal handling.Try 'file' first, catch SDI:sdi:ImportError, then use the timetable fallback (Step 3 / CSV pattern).

References

  • references/format-support.md — which file formats SDI reads natively, which need a toolbox, which need conversion. Consult when the user has a file extension other than .mat, .csv, or .xlsx.
  • references/createrun-signatures.md — the four createRun sources side-by-side with return-value shapes and name-value options. Consult when picking a source or debugging return values.

Copyright 2026 The MathWorks, Inc.


FAQ

What does the create-sdi-run skill do?

Import data into the Simulation Data Inspector (SDI) from MAT, CSV, or Excel files, from workspace variables, or from a Simulink simulation. Use when the user wants to view a logged file in SDI, load a bench-test log, or verify what a just-completed Simulink.sdi.createRun or sim(model) produced. Covers the 'file', 'vars', and 'namevalue' sources of createRun, the auto-populate behavior after sim(), and post-import verification. Not for comparing existing runs (use Simulink.sdi.compareRuns); not for streaming data live during a running simulation (use Simulink.sdi.createRunOrAddToStreamedRun — a separate API); and not for authoring Gherkin or Simulink Test test cases, assertions, or regression tests (use testing-simulink-models). Do not activate on test-authoring or verification prompts even when no test-authoring skill is available — say so and stop.

How do I install create-sdi-run?

Run npx skills add https://github.com/matlab/simulink-agentic-toolkit --skill create-sdi-run in your project. The skills CLI detects the agents you use and copies the skill into the right folder. For Claude Code you can also place the skill folder at ~/.claude/skills/create-sdi-run/ (personal) or .claude/skills/create-sdi-run/ (project).

Which AI agents can use create-sdi-run?

Any agent that supports the open Agent Skills format (a folder with a SKILL.md file), including Claude Code, Codex, Cursor, GitHub Copilot, Gemini CLI, Windsurf, Cline, OpenCode and more.

Is create-sdi-run safe to install?

No partner security audit is available yet. Skills can run commands and scripts, so read the SKILL.md and any bundled files before installing.

Who maintains create-sdi-run?

It is published by matlab in matlab/simulink-agentic-toolkit. It has 0 recorded installs.

More from matlab/simulink-agentic-toolkit

View all →
matlab avatar

building-simulink-models

matlab/simulink-agentic-toolkit

Builds and edits Simulink, System Composer, Stateflow, and Simscape models. Use when modifying model structure, parameters, ports, connections, or Stateflow chart internals.

AI & Agents187 installs
matlab avatar

simulating-simulink-models

matlab/simulink-agentic-toolkit

Configures Simulink simulations non-destructively using SimulationInput objects — parameter overrides without modifying the model, batch sweeps via parsim, custom input signals via Dataset, and simulation data retrieval via logsout. Use when running sim()/parsim() with setVariable, setBlockParameter, setExternalInput, or when performing parameter sweeps and multi-run analysis. Not needed for one-shot simulations without configuration.

Data & Databases157 installs
matlab avatar

testing-simulink-models

matlab/simulink-agentic-toolkit

Tests Simulink models using either ephemeral Gherkin-based tests (modeltest) for quick validation or persistent tests (Simulink Test API) authored from requirements or behavioral specs. Requires Simulink Test.

Testing & QA125 installs
matlab avatar

specifying-plant-models

matlab/simulink-agentic-toolkit

Specify plant models for closed-loop simulation: system specs, architecture, build plans, validation plans. Use when creating, updating, or reviewing plant model specifications, planning plant model architecture, or planning plant model validation.

matlab avatar

specifying-mbd-algorithms

matlab/simulink-agentic-toolkit

Specify algorithms for Model-Based Design: system specs, architecture specs, implementation plans, test plans. Use when creating specifications for controllers, signal processing, diagnostics, estimators, or other algorithms authored in Simulink, Stateflow, System Composer, or MATLAB Function blocks.

AI & Agents91 installs
matlab avatar

generate-requirement-drafts

matlab/simulink-agentic-toolkit

Generates draft requirements from Simulink models. Use when drafting or updating requirement artifacts from a model. Prefers Requirements Toolbox (.slreqx) when available; falls back to structured YAML.

AI & Agents81 installs

Popular testing & qa skills

View category →
mattpocock avatar

tdd

mattpocock/skills

Test-driven development. Use when the user wants to build features or fix bugs test-first, mentions "red-green-refactor", or wants integration tests.

Testing & QA1.3M installs
mattpocock avatar

grilling

mattpocock/skills

Grill the user relentlessly about a plan, decision, or idea. Use when the user wants to stress-test their thinking, or uses any 'grill' trigger phrases.

Testing & QA1.2M installs
mattpocock avatar

migrate-to-shoehorn

mattpocock/skills

Migrate test files from as type assertions to @total-typescript/shoehorn. Use when user mentions shoehorn, wants to replace as in tests, or needs partial test data.

Testing & QA553.6K installs
lllllllama avatar

run-train

lllllllama/rigorpilot-skills

Rigor Train skill for deep learning research repositories. Use when a documented or selected training command should be run conservatively for startup verification, short-run verification, full kickoff, or resume, with command, config, seed, log, checkpoint, status, and metric evidence written to standardized trainoutputs/. Do not use for environment setup, exploratory sweeps, speculative idea implementation, or end-to-end orchestration.

Testing & QA364.5K installs
obra avatar

test-driven-development

obra/superpowers

Use when implementing any feature or bugfix, before writing implementation code

Testing & QA289.3K installs

Use when implementation is complete, all tests pass, and you need to decide how to integrate the work

Testing & QA240K installs